Learn
Short objectives point to reviewed public explanations and exact boundaries.
View plansRole-based training for owners, buyers, technicians, shops, fleets, electrified vehicles, hardware access, parts decisions, and premium custody. Every school ends with decisions you can defend.
Short objectives point to reviewed public explanations and exact boundaries.
Case simulations force a next choice with evidence, cost, and safety consequences.
Mastery checks explain every answer and require an evidence-based passing score.
Field missions turn the method into a cleaner real-world scan or handoff.
0/40 applied lessons · 0/10 mastery checks passed
This public Academy record stays in this browser. The iOS app can recommend lessons from a scan without uploading vehicle evidence.
Foundation · Drivers, families, new owners
Respond to a warning without erasing the evidence or turning a code into a parts order.
Triage warning urgency
Preserve the original scan
Explain code status
Verify a repair outcome
Separate stop-now conditions from evidence that can be captured safely.
Read the reporting system and detected condition without naming an unproven part.
Use code status to understand where the observation sits in the confirmation cycle.
Capture the warning, operating state, code channels, freeze frame, and limitations.
Foundation · Hands-on owners and apprentices
Build a testable hypothesis and choose the smallest safe measurement that separates it from alternatives.
Form competing hypotheses
Choose discriminating tests
Recognize evidence gaps
Avoid parts-cannon reasoning
Move from observation to ranked causes, decisive tests, repair, and equivalent verification.
Use freeze-frame values as one operating scene instead of isolated thresholds.
Preserve time, state, recurrence, and environmental evidence before it disappears.
Choose between supply, network, fuel, and authorization evidence without guessing.
Intermediate · DIY, technicians, shop diagnosticians
Turn live parameters, voltage behavior, monitor results, and operating state into comparable evidence.
Build state-aware baselines
Correlate related signals
Interpret fuel correction
Screen supply-voltage effects
Compare cold start, warm idle, steady state, and controlled load with known units and provenance.
Compare total correction, banks, and operating states without calling the cause prematurely.
Retain raw identifiers when exact scaling or definitions are unavailable.
Separate unmetered air, delivery, sensing, and operating-context paths.
Foundation · Private buyers, dealers, inspectors
Detect reset evidence, preserve uncertainty, and combine electronic findings with a real inspection.
Read readiness as reset evidence
Recognize clean-scan limits
Build a buyer evidence packet
Explain risk without a fake lemon verdict
Record all code channels, readiness, identity, warning state, and unavailable modules.
Separate supported, complete, incomplete, and unsupported monitor states.
Decide what a no-code scan means when catalyst and EVAP have not run.
Document what was inspected, what was unavailable, and which independent checks remain.
Advanced · Technicians, advisors, independent shops
Create a technician-ready record that survives handoffs, reduces comebacks, and proves what changed.
Scope module coverage
Package diagnostic evidence
Write defensible findings
Close the verification loop
State the diagnostic layer, reporting module, exact definition source, and unavailable functions.
Compare codes, status, monitor completion, and measured behavior before and after.
Choose a release decision when a symptom is gone but the monitor has not rerun.
Produce observed facts, hypotheses, proving tests, result, and remaining unknowns.
Intermediate · Fleet managers, rental operators, custodians
Compare departure and return evidence without overstating causation, identity, or driver behavior.
Create custody baselines
Compare state changes
Flag reviewable events
Protect privacy and attribution
Capture identity, warnings, codes, readiness, mileage context, and visible condition before custody changes.
Keep time, operating state, recurrence, and limitations attached to an event.
Separate a newly observed fault from an unsupported allegation about who caused it.
Compare before/after facts and route anomalies to a qualified review.
Advanced · Owners, buyers, service professionals
Interpret low-voltage, cell or block behavior, state estimates, and capacity evidence without crossing high-voltage safety boundaries.
Separate SOC from SOH
Screen 12V dependencies
Evaluate repeatable imbalance
Escalate high-voltage hazards
Relate supply voltage, operating state, charging behavior, and network symptoms.
Separate cell or block spread, temperature, resistance estimates, state, and usable capacity.
Rank repeatability, temperature, load, code, and exact-profile evidence.
Recognize how 12V instability can create broad communication and wake-up symptoms.
Advanced · Power users, shops, profile evaluators
Understand the exact chain from phone and adapter through protocol, software, license, gateway, vehicle, and function.
Specify exact hardware identity
Separate access layers
Recognize gateway authority
Publish bounded compatibility evidence
Compare BLE, Wi-Fi, firmware, electrical behavior, and protocol reliability.
Prevent a connector or engine-scan success from becoming an all-system claim.
Treat authentication, subscription, role, geography, and vehicle state as exact dependencies.
Record exact hardware, firmware, platform, vehicle, module, function, and signed result.
Intermediate · Owners, buyers, technicians, advisors
Establish exact part identity before comparing sellers, prices, condition, or delivery.
Anchor exact manufacturer numbers
Separate fitment from similarity
Evaluate seller and condition risk
Preserve repair uncertainty
Use vehicle application, brand, exact manufacturer number, suffix, position, and supersession evidence.
Keep code-directed testing separate from parts sourcing.
Reject a cheaper listing when interchange, position, or revision evidence does not match.
Document the installed identifier and repeat the original proving condition.
Advanced · Exotic owners, fleets, service coordinators
Protect high-value vehicles with custody-grade evidence and lawful security-service intake—without publishing bypass instructions.
Create premium custody records
Minimize sensitive data
Verify service authority
Escalate exact OEM workflows
Keep topology, coverage, battery, mileage, warnings, and condition evidence scoped to the exact platform.
Identify when customer-supplied credentials, subscriptions, or authorized facilities are required.
Build a neutral before-and-after record without unsupported causation.
Teach identity, ownership, custody, consent, audit, and provider handoff without operational bypass content.
When all ten mastery checks are passed, create a private printable record showing the curriculum version and completed competencies. It never impersonates an industry license or OEM qualification.
Pass 10 more mastery checkpoints to unlock printing.
ScanWrench completion records show which curriculum version and mastery checks a learner completed.
They do not represent ASE certification, OEM authorization, a repair license, high-voltage qualification, locksmith authority, or permission to command a vehicle.
Key-service content covers lawful intake, identity, ownership, custody, consent, audit, and qualified-provider handoff. It excludes bypass instructions.